Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Cooling Principle

The working fluid (water or other liquid) circulates in the coil of the closed cooling tower, and the heat of the working fluid is dispersed into the water through the coil.

 

At the same time, the air outside the unit enters from the air inlet grille on the double side, perpendicular to the flow direction of the water, and transversally flows through the coil, a small part of the water evaporates and absorbs the heat, and the hot and humid air is discharged into the atmosphere by the fan at the top of the cooling tower.

 

The rest of the water falls into the tank at the bottom of the cooling tower, and is recirculated by the pump to the water distribution system, and then poured back to the coil through the packing.

 

Product Characteristics

HBY type double intake cross-flow closed cooling tower, as single intake cross-flow extension tower, the revolutionary cooler is placed at the bottom, through the access channel and the intake grille efficient maintenance.

 

The inlet and outlet are at the bottom to facilitate access to the main pipe. The double intake cross-flow closed cooling tower solves the problem of insufficient flow of a single intake cross-flow closed tower, and the maximum overflow of a single tower reaches 700m³/h.

 

Parameter

Outline Diagram

Parameter

 

Model

Dimension (mm)

Fan

Spray Pump

Device Port (DN)

Weight(kg)

L

W

H

Power
(kw)

Power
(kw)

Inlet

Outlet

Overflow

Drain

Make-up

Net

Operating

HBY-29C

7400

3200

3950

4*5

3.7*2

150*2

150*2

40*2

40*2

40*2

6800

16000

HBY-34A

7400

3200

3950

4*5

3.7*2

150*2

150*2

40*2

40*2

40*2

7500

17500

HBY-34B

7800

3400

3950

5.5*5

5.5*2

200*2

200*2

40*2

40*2

40*2

8200

19000

HBY-34C

7800

3400

3950

5.5*5

5.5*2

200*2

200*2

40*2

40*2

40*2

8600

19600

HBY-34D

8400

3400

3950

7.5*5

5.5*2

200*2

200*2

40*2

40*2

40*2

9000

20200

HBY-36A

8800

3600

3950

5.5*6

7.5*2

200*2

200*2

40*2

40*2

40*2

9500

22000

HBY-36B

8800

3600

3950

5.5*6

7.5*2

200*2

200*2

40*2

40*2

40*2

10000

22700

HBY-36C

9200

3600

3950

7.5*6

7.5*2

200*2

200*2

40*2

40*2

40*2

10800

23800

 

Design condition:

1.Inlet temperature 37℃, outlet temperature 32℃, wet bulb temperature 28℃, dry bulb temperature 31.5℃, atmospheric pressure P=99.4kPa;

2.Flow range: 83.3L/ S-194.4L/S;

3.This parameter table only provides some models, if you need other models, please contact the sales engineer;

4.Our company reserves the right to modify the parameter table later, if you need the latest version, please contact the sales engineer;