Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Cooling Principle

The working fluid (water or other liquid) circulates in the coil of the closed cooling tower, and the heat of the working fluid is dispersed into the water through the coil.

 

At the same time, the air outside the unit enters from the air inlet grille on the side, perpendicular to the flow direction of the water, and transversally flows through the coil, a small part of the water evaporates and absorbs the heat, and the hot and humid air is discharged into the atmosphere by the fan at the top of the cooling tower.

 

The rest of the water falls into the tank at the bottom of the cooling tower, and is recirculated by the pump to the water distribution system, and then poured back to the coil through the packing.

 

Product Characteristics

HBY type One side cross-flow closed cooling tower,adopts the advanced cooling tower design concept, from the heat transfer, structure, material science and many other scientific integration, the cooler is placed at the bottom, through the inspection channel and the air intake grille can be repaired.

 

The use of water collectors can reduce the evaporation. The inlet and outlet is placed under to facilitate access to the main pipeline. The sink drain is set at the bottom, which makes the discharge more convenient and effective.

 

Parameter

Outline Diagram

 

Parameter

 

Model

 

Dimension (mm)

Fan

Spray Pump

Device Port (DN)

Weight(kg)

L

 W

H

Power
(kw)

Power
(kw)

Inlet

Outlet

Overflow

Drain

Make
-up

Net

Operating

HBY-19A

2800

1840

2150

1.1*2

0.75

65

65

25

25

25

1050

2500

HBY-19B

2900

1840

2150

1.1*2

0.75

80

80

25

25

25

1170

2600

HBY-19C

2900

1840

2270

1.1*2

1.5

80

80

25

25

25

1210

2750

HBY-19D

3100

1940

2370

1.1*3

1.5

80

80

25

25

25

1320

3000

HBY-19E

3300

1940

2585

1.1*3

1.5

100

100

25

25

25

1430

3150

HBY-19F

3500

1940

2585

1.1*3

1.5

100

100

25

25

25

1600

3600

HBY-22A

4200

2240

3070

1.1*4

2.2

125

125

25

25

25

2250

5050

HBY-22B

4200

2240

3070

1.1*4

2.2

125

125

25

25

25

2350

5350

HBY-22C

4400

2240

3070

1.5*4

2.2

125

125

25

25

25

2500

6150

HBY-22D

4600

2240

3070

1.5*4

2.2

150

150

40

40

40

2600

6300

HBY-22E

4800

2240

3120

1.5*4

2.2

150

150

40

40

40

2850

6850

HBY-22F

5440

2240

3500

2.2*4

3.7

150

150

40

40

40

3600

8300

HBY-22G

5440

2240

3500

2.2*4

3.7

200

200

40

40

40

4000

9000

HBY-26A

5900

2600

3580

3*4

5.5

200

200

40

40

40

4520

10500

HBY-26B

5900

2600

3580

3*4

5.5

200

200

40

40

40

4700

11500

HBY-29A

6600

2900

3950

4*4

7.5

150*2

150*2

40

40

40

5100

13500

HBY-29B

6600

2900

3950

4*4

7.5

150*2

150*2

40

40

40

6000

14300

 

Design condition:

1.Inlet temperature 37℃, outlet temperature 32℃, wet bulb temperature 28℃, dry bulb temperature 31.5℃, atmospheric pressure P=99.4kPa;

2.Flow range: 7L/ S-76.4 L/S;

3.This parameter table only provides some models, if you need other models, please contact the sales engineer;

4.Our company reserves the right to modify the parameter table later, if you need the latest version, please contact the sales engineer;