Zipper closure 1/5 zip athletic pullovers for men. Stretchy, lightweight, fast-drying fabric for superior performance. REGULAR FIT - US standard sizes. An athletic fit that sits close to the body for a wide range of motion, designed for optimal performance and all day comfort. FEATURES - Quarter zip closure;Thumbholes on long sleeves to keep them in place during workout
Product Characteristics

The overall structure is solid and light, and the body and water tray are made of reinforced glass fiber (FRP glass steel), which will never corrode. The surface paint with ultraviolet inhibitor can resist the damage of sunlight;

 

Using specially designed PVC water curtain, the spatter effect is remarkable, the pressure drop loss is slight, and the spatter loss is less than 0.001%.

 

Specially designed water diffuser, large diameter, will not block, and the water dispersing effect is good, installed in the tower body is not polluted by external dust and debris.The honeycomb vacuum forming heat sink is adopted, and the surface of the staggered arrangement has grooves, and the heat exchange effect is good.Water tray adopts inclined design, easy to clean, less water, low operating weight.

Parameter

Outline Diagram

 

Parameter

 

Model

 Dimension (mm)

Fan

Device Port (DN)

Weight(kg)

Tower Head

 H

D

Power
(kw)

Diameter
(mm)

Inlet

Outlet

Overflow

Drain

Make-up

Net

Operating

MH2O

HKWY-17A

1740

1060

0.18

670

40

40

25

25

15

72

197

2

HKWY-17B

1960

1060

0.18

670

40

40

25

25

15

78

255

2

HKWY-17C

2000

1200

0.18

670

50

50

25

25

15

85

393

2

HKWY-17D

2290

1430

0.55

770

80

80

25

25

15

142

527

2

HKWY-17E

2360

1620

0.75

770

80

80

25

25

15

161

618

2.3

HKWY-17F

2595

2000

1.5

970

80

80

25

25

15

315

705

2.3

HKWY-21A

2690

2180

1.5

1170

100

100

25

25

25

401

1177

2.3

HKWY-21B

2790

2180

1.5

1170

100

100

40

25

25

458

1237

2.3

HKWY-21C

2875

2750

2.2

1470

100

100

40

25

25

547

1402

2.8

HKWY-21D

2950

3070

2.2

1470

125

125

50

25

25

618

1742

3

HKWY-21E

3200

3300

3.7

1750

125

125

50

50

25

661

2641

3

HKWY-21F

3300

3300

3.7

1750

125

125

50

50

25

749

2712

3.2

HKWY-21G

3600

3770

3.7

1750

150

150

50

50

40

978

3518

3.2

HKWY-21H

3960

3770

5.5

2400

200

200

50

50

40

1105

3650

3.6

HKWY-33A

4150

4790

7.5

2400

200

200

50

50

40

1380

4639

3.6

HKWY-33B

4150

4790

7.5

2400

200

200

50

50

40

1462

4719

4

HKWY-33C

5200

5480

11

3000

250

250

80

80

40

2302

6942

4

HKWY-33D

5260

5580

11

3000

250

250

80

80

40

2578

7216

4

HKWY-42A

5770

6600

15

3400

250

250

80

80

40

3604

9120

5

HKWY-42B

5820

6600

15

3400

250

250

80

80

40

3807

10300

5.5

HKWY-42C

5920

7600

22

3600

300

300

80

80

40

4680

12270

6

 

Design condition:

1.Inlet temperature 37℃, outlet temperature 32℃, wet bulb temperature 28℃, dry bulb temperature 31.5℃, atmospheric pressure P=99.4kPa;

2.Flow range:27.8L/ S-166.7L/S;

3.This parameter table only provides some models, if you need other models, please contact the sales engineer;